Near-surface petrochemical sensing using coplanar waveguides
Type
Master thesisNot peer reviewed

View/ Open
Date
2015-09-11Author
Metadata
Show full item recordAbstract
The project studies the ability of coplanar waveguide sensor in sensing thin layers of petrochemical liquid. A coplanar waveguide is
built on flexible printable circuit board partially based on an existing design. Two sensors are constructed with the coplanar waveguide
to test the industrial applicability of sensor mounted on the inside of pipe wall. Simulation tool are used to examine the viability of
incorporating simulation in microwave frequency experiments and sensor design. The experiments focus on performance of the sensors and
place emphasis on the measurement output of liquid with non-uniform thickness.
The test liquid stays above the entire surface of the coplanar waveguide sensor. At the side of the sensor, a vertical transition is
implemented to connect coplanar waveguide to coaxial one. Microwave frequency range signal is excited at the ports, and interacts with
the liquid as it is transmitted on the coplanar waveguide. The effective permittivity, influenced by both the thickness and the
permittivity of the test liquid above the coplanar waveguide, affects the characteristic of the transmission of the wave between the
ports. Thus, the measured S-parameters can be used to interpret the permittivity.
The sensors in the project produce more accurate permittivity measurements than the old prototype for frequencies below 200 MHz. The
viability of coplanar waveguide built on flexible printed circuit board is therefore verified as effective in near-surface permittivity
measurements. Bending of the coplanar waveguide has minimum influence on the measurements. It is therefore concluded that it should be
possible to place it in-line on the pipe wall. The simulation software is confirmed to be stable in producing realistic result within
the frequency range and permittivity range in the project. Non-uniform thin layers of the petroleum products can be measured by
permittivity measurement using the coplanar waveguide sensors. A small change in effective permittivity caused by thickness variation
can be detected regardless of the type of test liquid. The calculated effective permittivity of test liquid does not vary as long as the
average thickness across the sensor area is the same. The thickness non-uniformity therefore does not affect significantly the effective
permittivity of the test liquid.
Publisher
The University of BergenCollections
Copyright the Author. All rights reserved