Vis enkel innførsel

dc.contributor.authorErchinger, Friedemann Georgen_US
dc.contributor.authorEngjom, Tronden_US
dc.contributor.authorGudbrandsen, Oddrun Anitaen_US
dc.contributor.authorTjora, Erlingen_US
dc.contributor.authorGilja, Odd Helgeen_US
dc.contributor.authorDimcevski, Georg Gjorgjien_US
dc.date.accessioned2017-03-31T07:53:01Z
dc.date.available2017-03-31T07:53:01Z
dc.date.issued2016-02-03
dc.PublishedPancreatology 2016, 16(2):231-237eng
dc.identifier.issn1424-3911
dc.identifier.urihttps://hdl.handle.net/1956/15631
dc.description.abstractObjectives We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Methods Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. Results 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) Conclusions The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution.en_US
dc.language.isoengeng
dc.publisherElseviereng
dc.relation.ispartof<a href="http://hdl.handle.net/1956/17788" target="blank"> A short endoscopic Secretin test for the diagnosis of chronic pancreatitis</a>
dc.rightsAttribution CC BY NC NDeng
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/eng
dc.subjectPancreatic disorderseng
dc.subjectPancreatic function testeng
dc.subjectPancreatic juiceeng
dc.subjectSecretineng
dc.subjectShort endoscopic secretin testeng
dc.subjectBicarbonateeng
dc.titleAutomated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration methoden_US
dc.typePeer reviewed
dc.typeJournal article
dc.date.updated2016-12-13T14:45:28Z
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2016 the authors
dc.identifier.doihttps://doi.org/10.1016/j.pan.2016.01.010


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution CC BY NC ND
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution CC BY NC ND