    • Intramedullary Nails Result in More Reoperations Than Sliding Hip Screws in Two-part Intertrochanteric Fractures 

      Matre, Kjell; Havelin, Leif Ivar; Gjertsen, Jan-Erik; Espehaug, Birgitte; Fevang, Jonas Meling (Springer, 2013-04-01)
      Background Sliding hip screws (SHSs) and intramedullary (IM) nails are well-documented implants for simple two-part intertrochanteric fractures; however, there is no consensus regarding which type of implant is ...
      Peer reviewedJournal article
    • TRIGEN INTERTAN Intramedullary Nail Versus Sliding Hip Screw 

      Matre, Kjell; Vinje, Tarjei; Havelin, Leif Ivar; Gjertsen, Jan-Erik; Furnes, Ove; Espehaug, Birgitte; Kjellevold, Stein-Harald; Fevang, Jonas Meling (Journal of bone and joint surgery, 2013-02-06)
      Background: Both intramedullary nails and sliding hip screws are used with good results in the treatment of intertrochanteric and subtrochanteric fractures. The aim of our study was to assess whether use of the TRIGEN ...