Vis enkel innførsel

dc.contributor.authorBratke, Heiko
dc.contributor.authorMargeirsdottir, Hanna D.
dc.contributor.authorAssmus, Jörg
dc.contributor.authorNjølstad, Pål Rasmus
dc.contributor.authorSkrivarhaug, Torild
dc.date.accessioned2022-03-03T10:46:08Z
dc.date.available2022-03-03T10:46:08Z
dc.date.created2021-08-27T09:19:49Z
dc.date.issued2021
dc.identifier.issn1869-6961
dc.identifier.urihttps://hdl.handle.net/11250/2982759
dc.description.abstractObjective To examine the use of multiple daily injections (MDI), insulin pumps, self-measured blood glucose (SMBG), and continuous glucose monitoring (CGM) systems, and their association with glycated hemoglobin (HbA1c), diabetic ketoacidosis (DKA), and severe hypoglycemia. Methods In a pediatric population-based nationwide cross-sectional study, we analyzed data from 2623 participants up to 18 years of age with type 1 diabetes, using 2017 annual data from the Norwegian Childhood Diabetes Registry. HbA1c was adjusted for age, gender, and diabetes duration. Using a linear mixed-effects model, we assessed HbA1c and the incidence of DKA and severe hypoglycemia according to the use of MDI, insulin pumps, SMBG, and CGM. Results We observed that 74.7% of participants were using an insulin pump and 52.6% were using a CGM system. Mean HbA1c was 7.8% (62 mmol/mol). The HbA1c of pump users was 0.14 percentage points (pp) higher than that of MDI users. Fewer pump users than MDI users achieved an HbA1c of < 7.5% (38.3 vs. 41.6%). CGM users had a 0.18 pp lower HbA1c than SMBG users, with 40.5 and 38.0%, respectively, achieving an HbA1c of < 7.5%. The incidence of severe hypoglycemia or hospitalization due to DKA was not different in pump and CGM users compared with nonusers. Compared with other insulin pumps, patch pump use was associated with a significantly lower odds ratio for DKA. Conclusions Despite the broad use of diabetes technology, as many as 61% of our pediatric cohort did not reach the HbA1c target recommended by the International Society for Pediatric and Adolescent Diabetes (ISPAD). Lower HbA1c was associated with CGM use but not with insulin pump use. Acute complications were not less frequent in the groups using insulin pumps or CGM compared with those using MDI and SMBG. Further research is required to explore the lower incidence of DKA among patch pump users.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleDoes Current Diabetes Technology Improve Metabolic Control? A Cross-Sectional Study on the Use of Insulin Pumps and Continuous Glucose Monitoring Devices in a Nationwide Pediatric Populationen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright The Author(s) 2021en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1007/s13300-021-01127-6
dc.identifier.cristin1929153
dc.source.journalDiabetes Therapyen_US
dc.source.pagenumber2571–2583en_US
dc.identifier.citationDiabetes Therapy. 2021, 12, 2571–2583.en_US
dc.source.volume12en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal