Vis enkel innførsel

dc.contributor.authorBjørge, Joachim Søreng
dc.contributor.authorBjørkheim, Svein Arne
dc.contributor.authorLog, Maria-Monika Metallinou
dc.contributor.authorLog, Torgrim
dc.contributor.authorFrette, Øyvind
dc.date.accessioned2019-12-19T12:11:11Z
dc.date.available2019-12-19T12:11:11Z
dc.date.issued2019-06-19
dc.PublishedBjørge JS, Bjørkheim SA, Log M, Log T, Frette Ø. Influence of Acetone and Sodium Chloride Additives on Cooling Efficiency of Water Droplets Impinging onto Hot Metal Surfaces. Energies. 2019;12:2358eng
dc.identifier.issn1996-1073en_US
dc.identifier.urihttps://hdl.handle.net/1956/21191
dc.description.abstractIn the present work, the cooling efficiency of water droplets falling onto hot aluminum and stainless steel discs from heights of 12.5 cm, 25 cm, 50 cm and 100 cm, corresponding to speeds of 1.5 m/s, 2.2 m/s, 3.1 m/s and 4.4 m/s, respectively, were studied. The discs were aligned at 0° (horizontal), 30° and 60° inclination. The water application rate was 0.022 g/s and the droplet diameters studied were 2.5 mm, 3.2 mm and 3.7 mm. Acetone solutions (300 ppm and 700 ppm) as well as a NaCl (35 g/kg) solution, emulating seawater, were tested to evaluate the influence of an active surfactant on the recorded cooling efficiency. The droplets with higher impact speed resulted in lower cooling efficiency, especially at disc temperatures above the Leidenfrost temperature, likely due to more vigorous droplets bouncing. Larger inclination did, as expected, result in lower cooling efficiency. At temperatures associated with nucleate boiling, the water droplets with NaCl conspicuously displayed higher cooling efficiency at about 110 °C. However, at temperatures between 120 °C and the Leidenfrost temperature, acetone and NaCl additives did not significantly alter the cooling efficiency of the water droplets. Above the Leidenfrost temperature, a minor increase in cooling efficiency was observed for the acetone solutions. Overall, the additives only marginally changed the water droplet cooling efficiency. The standard industrial water application rate (i.e., 10 L/min∙m2) is shown to be insufficient compared to the heat fluxes expected in pool and jet fires (i.e., 250 kW/m2 and 350 kW/m2, respectively).en_US
dc.language.isoengeng
dc.publisherMDPIen_US
dc.rightsAttribution CC BYeng
dc.rights.urihttp://creativecommons.org/licenses/by/4.0eng
dc.subjecthot metalseng
dc.subjectwater droplet cooling efficiencyeng
dc.subjectacetoneeng
dc.subjectNaCleng
dc.titleInfluence of Acetone and Sodium Chloride Additives on Cooling Efficiency of Water Droplets Impinging onto Hot Metal Surfacesen_US
dc.typePeer reviewed
dc.typeJournal article
dc.date.updated2019-08-09T11:42:56Z
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2019 The Author(s)en_US
dc.identifier.doihttps://doi.org/10.3390/en12122358
dc.identifier.cristin1707000
dc.source.journalEnergies
dc.relation.projectAndre: PO 4500024195
dc.relation.projectNorges forskningsråd: 257901


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution CC BY
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution CC BY