Vis enkel innførsel

dc.contributor.authorSkranes, Julia Brox
dc.contributor.authorKleiven, Øyunn
dc.contributor.authorAakre, Kristin Moberg
dc.contributor.authorSkadberg, Øyvind
dc.contributor.authorMelberg, Tor Harald
dc.contributor.authorOmland, Torbjørn
dc.contributor.authorØrn, Stein
dc.date.accessioned2021-02-23T15:21:09Z
dc.date.available2021-02-23T15:21:09Z
dc.date.created2020-11-19T15:22:52Z
dc.date.issued2020
dc.PublishedJournal of the American Heart Association. 2020, 9 .
dc.identifier.issn2047-9980
dc.identifier.urihttps://hdl.handle.net/11250/2729935
dc.description.abstractBackground Use of snus, a smokeless tobacco product, is increasing in Scandinavia. Strenuous physical activity is associated with an acute increase in high‐sensitivity cardiac troponin (swhs‐cTn) concentrations. Current smoking is associated with lower hs‐cTn, but whether this also holds true for smokeless tobacco and whether tobacco affects the hs‐cTn response to exercise remain unknown. Methods and Results We measured hs‐cTnI and hs‐cTnT concentrations in 914 recreational athletes before and 3 and 24 hours after a 91‐km bicycle race. Self‐reported snus tobacco habits were reported as noncurrent (n=796) and current (n=118). The association between snus use and change in log‐transformed hs‐cTnI and hs‐cTnT concentrations (ie, the differences between concentrations at baseline and 3 hours and 24 hours ) were assessed by multivariable linear regression analysis. Concentrations of hs‐cTn at baseline were lower in current than in noncurrent snus users (hs‐cTnI median, 1.7 ng/L; Q1 to Q3: 1.6–2.3 versus 2.0 ng/L; Q1 to Q3: 1.6–3.2 [P=0.020]; and hs‐cTnT: median, 2.9 ng/L, Q1 to Q3: 2.9–3.5 versus 2.9 ng/L, Q1 to Q3: 2.9–4.3 [P=0.021]). In fully adjusted multivariable models, use of snus was associated with lower change in hs‐cTn concentrations from baseline to 3 hours (hs‐cTnI: −29% [P=0.002], hs‐cTnT: −18% [P=0.010]) and 24 hours (hscTnI: −30% [P=0.010], hs‐cTnT −19%, [P=0.013]). Conclusions Resting hs‐cTn concentrations are lower and the exercise‐induced cardiac troponin response is attenuated in current users of smokeless tobacco compared with nonusers. Further insight into the pathophysiological processes underlying the attenuated cardiac troponin response to exercise in tobacco users is needed. Registration URL: https://www.clini​caltr​ials.gov; Unique identifier: NCT02166216.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleHigh-Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014en_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2020 The Authors.en_US
dc.source.articlenumbere017363en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1161/JAHA.120.017363
dc.identifier.cristin1850019
dc.source.journalJournal of the American Heart Associationen_US
dc.source.409
dc.identifier.citationJournal of the American Heart Association. 2020, 9 (19), e017363en_US
dc.source.volume9en_US
dc.source.issue19en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal