A randomized trial of laryngeal mask airway in neonatal resuscitation
Pejovic, Nicolas; Höök, Susanna Myrnerts; Byamugisha, Josaphat; Alfvén, Tobias; Lubulwa, Clare; Cavallin, Francesco; Nankunda, Jolly; Ersdal, Hege Langli; Blennow, Mats; Trevisanuto, Daniele; Tylleskär, Thorkild
Journal article, Peer reviewed
Published version

View/ Open
Date
2020Metadata
Show full item recordCollections
Abstract
Background: Face-mask ventilation is the most common resuscitation method for birth asphyxia. Ventilation with a cuffless laryngeal mask airway (LMA) has potential advantages over face-mask ventilation during neonatal resuscitation in low-income countries, but whether the use of an LMA reduces mortality and morbidity among neonates with asphyxia is unknown.
Methods: In this phase 3, open-label, superiority trial in Uganda, we randomly assigned neonates who required positive-pressure ventilation to be treated by a midwife with an LMA or with face-mask ventilation. All the neonates had an estimated gestational age of at least 34 weeks, an estimated birth weight of at least 2000 g, or both. The primary outcome was a composite of death within 7 days or admission to the neonatal intensive care unit (NICU) with moderate-to-severe hypoxic–ischemic encephalopathy at day 1 to 5 during hospitalization.
Results: Complete follow-up data were available for 99.2% of the neonates. A primary outcome event occurred in 154 of 563 neonates (27.4%) in the LMA group and 144 of 591 (24.4%) in the face-mask group (adjusted relative risk, 1.16; 95% confidence interval [CI], 0.90 to 1.51; P=0.26). Death within 7 days occurred in 21.7% of the neonates in the LMA group and 18.4% of those in the face-mask group (adjusted relative risk, 1.21; 95% CI, 0.90 to 1.63), and admission to the NICU with moderate-to-severe hypoxic–ischemic encephalopathy at day 1 to 5 during hospitalization occurred in 11.2% and 10.1%, respectively (adjusted relative risk, 1.27; 95% CI, 0.84 to 1.93). Findings were materially unchanged in a sensitivity analysis in which neonates with missing data were counted as having had a primary outcome event in the LMA group and as not having had such an event in the face-mask group. The frequency of predefined intervention-related adverse events was similar in the two groups.
Conclusions: In neonates with asphyxia, the LMA was safe in the hands of midwives but was not superior to face-mask ventilation with respect to early neonatal death and moderate-to-severe hypoxic–ischemic encephalopathy.