Vis enkel innførsel

dc.contributor.authorLeung, Wai Chun
dc.date.accessioned2021-06-30T23:56:09Z
dc.date.available2021-06-30T23:56:09Z
dc.date.issued2021-06-14
dc.date.submitted2021-06-30T22:00:48Z
dc.identifier.urihttps://hdl.handle.net/11250/2762658
dc.description.abstractNew pixel sensors will be installed to the new Inner Tracker upgrade at the ATLAS detector. These sensor will have higher radiation tolerance than the ones currently on the Inner Detector. This thesis will concentrate on development of a test setup dedicated to testing the new pixel sensors. The Peltier Controller Temperature Monitor has been developed for this purpose. IV-curve measurements have also been done on RD53A sensor modules. The Peltier Controller Temperature Monitor has been successfully used in stage 1 qualification test of module testing in the University of Bergen. The Peltier Controller has also been proven to work quite well.
dc.language.isoeng
dc.publisherThe University of Bergen
dc.rightsCopyright the Author. All rights reserved
dc.subjectTest Setup
dc.subjectCERN
dc.subjectSilicon Pixel Module
dc.subjectITk
dc.subjectATLAS
dc.titleA Setup for Testing of Silicon Pixel Modules for the ITk Tracker in the ATLAS Experiment at CERN
dc.typeMaster thesis
dc.date.updated2021-06-30T22:00:48Z
dc.rights.holderCopyright the Author. All rights reserved
dc.description.degreeMasteroppgave i fysikk
dc.description.localcodePHYS399
dc.description.localcodeMAMN-PHYS
dc.subject.nus752199
fs.subjectcodePHYS399
fs.unitcode12-24-0


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel