Show simple item record

dc.contributor.authorWoyessa, Adugnaen_US
dc.contributor.authorDeressa, Wakgarien_US
dc.contributor.authorAli, Ahmeden_US
dc.contributor.authorLindtjørn, Bernten_US
dc.date.accessioned2014-03-24T15:01:24Z
dc.date.available2014-03-24T15:01:24Z
dc.date.issued2013-06-27eng
dc.identifier.issn1475-2875
dc.identifier.urihttps://hdl.handle.net/1956/7886
dc.description.abstractMalaria is a major public health problem in Ethiopia. Plasmodium falciparum and Plasmodium vivax co-exist and malaria rapid diagnostic test (RDTs) is vital in rendering parasite-confirmed treatment especially in areas where microscopy from 2008 to 2010 is not available. CareStartTM Malaria Pf/Pv combo test was evaluated compared to microscopy in Butajira area, south-central Ethiopia. This RDT detects histidine-rich protein-2 (HRP2) found in P. falciparum, and Plasmodium enzyme lactate dehydrogenase (pLDH) for diagnosis of P. vivax. The standard for the reporting of diagnostic accuracy studies was complied. Among 2,394 participants enrolled, 10.9% (n=87) were Plasmodium infected (household survey) and 24.5% (n=392) health facility-based using microscopy. In the household surveys, the highest positivity was caused by P. vivax (83.9%, n=73), P. falciparum (15.0%, n=13), and the rest due to mixed infections of both (1.1%, n=1). In health facility, P. vivax caused 78.6% (n=308), P. falciparum caused 20.4% (n=80), and the rest caused by mixed infections 1.0% (n=4). RDT missed 9.1% (n=8) in household and 4.3% (n=17) in health facility-based surveys among Plasmodium positive confirmed by microscopy while 3.3% (n=24) in household and 17.2% (n=208) in health facility-based surveys were detected false positive. RDT showed agreement with microscopy in detecting 79 positives in household surveys (n=796) and 375 positives in health centre survey (n=1,598). RDT performance varied in both survey settings, lowest PPV (64.3%) for Plasmodium and P. falciparum (77.2%) in health centres; and Plasmodium (76.7%) and P. falciparum (87.5%) in household surveys. NPV was low in P. vivax in health centres (77.2%) and household (87.5%) surveys. Seasonally varying RDT precision of as low as 14.3% PPV (Dec. 2009), and 38.5% NPV (Nov. 2008) in health centre surveys; and 40-63.6% PPV was observed in household surveys. But the influence of age and parasite density on RDT performance was not ascertained. Establishing quality control of malaria RDT in the health system in areas with low endemic and where P. falciparum and P. vivax co-exist is recommendable. CareStartTM RDT might be employed for epidemiological studies that require interpreting the results cautiously. Future RDT field evaluation against microscopy should be PCR corrected.en_US
dc.language.isoengeng
dc.publisherBioMed Centraleng
dc.rightsAttribution CC BYeng
dc.rights.urihttp://creativecommons.org/licenses/by/2.0/eng
dc.subjectCareStartTM RDTeng
dc.subjectMicroscopyeng
dc.subjectPrecisioneng
dc.subjectSeasoneng
dc.subjectHighlandeng
dc.subjectButajiraeng
dc.subjectEthiopiaeng
dc.titleEvaluation of CareStart (TM) malaria Pf/Pv combo test for Plasmodium falciparum and Plasmodium vivax malaria diagnosis in Butajira area, south-central Ethiopiaen_US
dc.typePeer reviewed
dc.typeJournal article
dc.date.updated2013-08-23T08:38:44Z
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2013 Woyessa et al.; licensee BioMed Central Ltd.
dc.rights.holderAdugna Woyessa et al.; licensee BioMed Central Ltd.
dc.source.articlenumber218
dc.identifier.doihttps://doi.org/10.1186/1475-2875-12-218
dc.identifier.cristin1045457
dc.source.journalMalaria Journal
dc.source.4012


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution CC BY
Except where otherwise noted, this item's license is described as Attribution CC BY