Vis enkel innførsel

dc.contributor.authorSikora, Marcin Pawelen_US
dc.contributor.authorMuzik, Janen_US
dc.contributor.authorSöhn, Matthiasen_US
dc.contributor.authorWeinmann, Martinen_US
dc.contributor.authorAlber, Markusen_US
dc.date.accessioned2011-10-24T13:51:58Z
dc.date.available2011-10-24T13:51:58Z
dc.date.issued2009-12-12eng
dc.PublishedRadiation Oncology 4(64)en
dc.identifier.issn1748-717X
dc.identifier.urihttps://hdl.handle.net/1956/5134
dc.description.abstractBackground: The purpose of the present study is to compare finite size pencil beam (fsPB) and Monte Carlo (MC) based optimization of lung intensity-modulated stereotactic radiotherapy (lung IMSRT). Materials and methods: A fsPB and a MC algorithm as implemented in a biological IMRT planning system were validated by film measurements in a static lung phantom. Then, they were applied for static lung IMSRT planning based on three different geometrical patient models (one phase static CT, density overwrite one phase static CT, average CT) of the same patient. Both 6 and 15 MV beam energies were used. The resulting treatment plans were compared by how well they fulfilled the prescribed optimization constraints both for the dose distributions calculated on the static patient models and for the accumulated dose, recalculated with MC on each of 8 CTs of a 4DCT set. Results: In the phantom measurements, the MC dose engine showed discrepancies < 2%, while the fsPB dose engine showed discrepancies of up to 8% in the presence of lateral electron disequilibrium in the target. In the patient plan optimization, this translates into violations of organ at risk constraints and unpredictable target doses for the fsPB optimized plans. For the 4D MC recalculated dose distribution, MC optimized plans always underestimate the target doses, but the organ at risk doses were comparable. The results depend on the static patient model, and the smallest discrepancy was found for the MC optimized plan on the density overwrite one phase static CT model. Conclusions: It is feasible to employ the MC dose engine for optimization of lung IMSRT and the plans are superior to fsPB. Use of static patient models introduces a bias in the MC dose distribution compared to the 4D MC recalculated dose, but this bias is predictable and therefore MC based optimization on static patient models is considered safe.en_US
dc.language.isoengeng
dc.publisherBioMed Centraleng
dc.relation.ispartof<a href="http://hdl.handle.net/1956/5135" target="_blank">Virtual Source Modelling of Photon Beams for Monte Carlo Based Radiation Therapy Treatment Planning</a>eng
dc.rightsAttribution CC BYeng
dc.rights.urihttp://creativecommons.org/licenses/by/2.0eng
dc.titleMonte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRTen_US
dc.typePeer reviewed
dc.typeJournal article
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2009 Sikora et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.identifier.doihttps://doi.org/10.1186/1748-717x-4-64
dc.subject.nsiVDP::Medical disciplines: 700::Clinical medical disciplines: 750::Oncology: 762eng


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution CC BY
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution CC BY