Vis enkel innførsel

dc.contributor.authorBentsen, Mariann
dc.contributor.authorMarkestad, Trond
dc.contributor.authorHalvorsen, Thomas
dc.date.accessioned2022-11-17T12:58:59Z
dc.date.available2022-11-17T12:58:59Z
dc.date.created2018-05-29T13:03:00Z
dc.date.issued2018
dc.identifier.issn2312-0541
dc.identifier.urihttps://hdl.handle.net/11250/3032461
dc.description.abstractEarly prediction of bronchopulmonary dysplasia (BPD) may facilitate tailored management for neonates at risk. We investigated whether easily accessible flow data from a mechanical ventilator can predict BPD in neonates born extremely premature (EP). In a prospective population-based study of EP-born neonates, flow data were obtained from the ventilator during the first 48 h of life. Data were logged for >10 min and then converted to flow–volume loops using custom-made software. Tidal breathing parameters were calculated and averaged from ≥200 breath cycles, and data were compared between those who later developed moderate/severe and no/mild BPD. Of 33 neonates, 18 developed moderate/severe and 15 no/mild BPD. The groups did not differ in gestational age, surfactant treatment or ventilator settings. The infants who developed moderate/severe BPD had evidence of less airflow obstruction, significantly so for tidal expiratory flow at 50% of tidal expiratory volume (TEF50) expressed as a ratio of peak tidal expiratory flow (PTEF) (p=0.007). A compound model estimated by multiple logistic regression incorporating TEF50/PTEF, birthweight z-score and sex predicted moderate/severe BPD with good accuracy (area under the curve 0.893, 95% CI 0.735–0.973). This study suggests that flow data obtained from ventilators during the first hours of life may predict later BPD in premature neonates. Future and larger studies are needed to validate these findings and to determine their clinical usefulness.en_US
dc.language.isoengen_US
dc.publisherEuropean Respiratory Societyen_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleVentilator flow data predict bronchopulmonary dysplasia in extremely premature neonatesen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright ERS 2018en_US
dc.source.articlenumber00099en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1183/23120541.00099-2017
dc.identifier.cristin1587422
dc.source.journalERJ Open Researchen_US
dc.identifier.citationERJ Open Research. 2018, 4 (1), 00099.en_US
dc.source.volume4en_US
dc.source.issue1en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal