Vis enkel innførsel

dc.contributor.authorNguyen, Long Giangen_US
dc.date.accessioned2016-09-29T09:14:35Z
dc.date.available2016-09-29T09:14:35Z
dc.date.issued2015-01-26
dc.date.submitted2015-01-26en_US
dc.identifier.urihttps://hdl.handle.net/1956/12873
dc.description.abstractBackground: Some patients do not tolerate polymethylmethacrylate-based (PMMA) dentures. Polyamide as an alternative to PMMA has, however, not been well documented regarding to biocompatibility and cytotoxicity. Aim: The purpose of this study was to determine in vitro the effect of eluates from polyamide denture base resin on apoptosis and necrosis. Materials and methods: Eluates from three auto-polymerized PMMA, an auto-polymerized vinyl polysiloxane, a heat-polymerized PMMA and two polyamide based resin were investigated. The characteristics of apoptosis and necrosis were evaluated by flow cytometry. Results: The results showed no statistical differences in cell death among the materials. Conclusion: No definitive conclusion could be drawn based on the results of this study. Further studies are needed in order to make a thorough evaluation of the biocompatibility of polyamide-based denture base materials.en_US
dc.description.abstractBakgrunn: Noen pasienter tolererer ikke polymetylmetakrylat baserte (PMMA) tannprotester. Polyamid er brukt som et alternativ til PMMA, men det mangler fortsatt dokumentasjon med hensyn til biokompatibilitet og cytotoksisitet. Mål: Hensikten med denne studien var å bestemme, in vitro, effekten av eluater fra polyamid protesebasis resin på apoptose og nekrose. Materialer og metoder: Eluater fra tre autopolymeriserte PMMA, en autopolymerisert vinyl polysiloksan, en varm polymerisert PMMA og to polyamid-basert resiner ble undersøkt. Kjennetegnene for apoptose og nekrose ble evaluert ved flow cytometri. Resultater: Resultatene viste ingen signifikant forskjell i celledød mellom de ulike materialene. Konklusjon: Basert på resultatene av denne studien kan ingen endelig konklusjon trekkes. Videre forsøk er nødvending for å kunne kartlegge biokompatibiliteten til polyamid-basert protese materialer.en_US
dc.format.extent928407 bytesen_US
dc.format.mimetypeapplication/pdfen_US
dc.language.isoengeng
dc.publisherThe University of Bergeneng
dc.rightsCopyright the Author. All rights reservedeng
dc.subjectpolymethylmethacrylateeng
dc.subjectPMMAeng
dc.subjectpolyamideeng
dc.subjectbiocompatibilityeng
dc.subjectcytotoxicityeng
dc.subject.meshPolymethyl Methacrylateeng
dc.subject.meshMaterials Testingeng
dc.titleCytotoxicity of eluates from denture base materialsen_US
dc.typeMaster thesis
dc.description.localcodeMAOD-ODONT
dc.description.localcodeOD3PROSJ
dc.subject.nus764106en_US
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk odontologiske fag: 830en_US
fs.subjectcodeOD3PROSJ


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel