Vis enkel innførsel

dc.contributor.authorBørve, Kristianeng
dc.date.accessioned2013-11-08T13:17:27Z
dc.date.available2013-11-08T13:17:27Z
dc.date.issued2013-08-23eng
dc.date.submitted2013-08-23eng
dc.identifier.urihttps://hdl.handle.net/1956/7518
dc.description.abstractThe aim of this work has been to design and test a refractometer for accurate measurement of seawater refractive index. The goal was to create a refractometer with a cylindrical embodiment and measure refractive indices with an accuracy of 10−6 refractive index units (RUI). The realization of the instrument resulted in a measurement chamber consisting of a cylindrical glass tube with an inner radius if 4 mm, thickness of 1 mm and length of 115 mm. To transverse the laser beam into the glass cylinder in a satisfactory way, the beam is directed by mirrors submerged in an immersion oil. The oil functions as a compensating" medium between the air-glass interface and was only used because desired embodiments were not available. The final refractometer design was decided after rigorous computer simulations. The experiments were conducted by measuring the laser beam displacement of sodium chloride solutions, with salinities ranging from 0 to 40 parts per thousand. A brief temperature measurement was also conducted. The results revealed that the instrument was able to short-term measurements with an accuracy of 1.5⋅10−5 RIU, but poor repeatability of the instrument decreased the overall accuracy to 2.9⋅10−4 RIU. The increased uncertainties is considered to be caused by either small displacements in the tweakable components in the setup or by slow drifts in the laser/detector caused by heating processes.en_US
dc.description.abstractThe aim of this work has been to design and test a refractometer for accurate measurement of seawater refractive index. The goal was to create a refractometer with a cylindrical embodiment and measure refractive indices with an accuracy of 10^{-6} refractive index units (RUI). The realization of the instrument resulted in a measurement chamber consisting of a cylindrical glass tube with an inner radius if 4 mm, thickness of 1 mm and length of 115 mm. To transverse the laser beam into the glass cylinder in a satisfactory way, the beam is directed by mirrors submerged in an immersion oil. The oil functions as a compensating" medium between the air-glass interface and was only used because desired embodiments were not available. The final refractometer design was decided after rigorous computer simulations. The experiments were conducted by measuring the laser beam displacement of sodium chloride solutions, with salinities ranging from 0 to 40 parts per thousand. A brief temperature measurement was also conducted. The results revealed that the instrument was able to short-term measurements with an accuracy of 1.5 * 10^{-5} RIU, but poor repeatability of the instrument decreased the overall accuracy to 2.9 * 10^{-4} RIU. The increased uncertainties is considered to be caused by either small displacements in the tweakable components in the setup or by slow drifts in the laser/detector caused by heating processes.en_US
dc.format.extent6393397 byteseng
dc.format.mimetypeapplication/pdfeng
dc.language.isoengeng
dc.publisherThe University of Bergenen_US
dc.subjectrefractometereng
dc.subjectrefractive indexeng
dc.subjectoptical state seawatereng
dc.titleMeasurement of seawater by refractometric methodsen_US
dc.typeMaster thesis
dc.rights.holderCopyright the author. All rights reserveden_US
dc.description.degreeMaster i Fysikken_US
dc.description.localcodeMAMN-PHYS
dc.description.localcodePHYS399
dc.subject.nus752199eng
fs.subjectcodePHYS399


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel