Vis enkel innførsel

dc.contributor.authorSchriwer, Christian
dc.contributor.authorGjerdet, Nils Roar
dc.contributor.authorArola, Dwayne
dc.contributor.authorØilo, Marit
dc.date.accessioned2021-08-11T09:24:09Z
dc.date.available2021-08-11T09:24:09Z
dc.date.created2021-05-10T16:19:22Z
dc.date.issued2021
dc.identifier.issn0109-5641
dc.identifier.urihttps://hdl.handle.net/11250/2767340
dc.description.abstractObjective Monolithic zirconia crowns have become a viable alternative to conventional layered restorations. The aim of this study was to evaluate whether the taper, and thus wall thickness, of the abutment or pre-defined cement space affect the fracture resistance or fracture mode of monolithic zirconia crowns. Methods A model tooth was prepared with a taper of 15° and a shallow circumferential chamfer preparation (0.5 mm). Two additional models were made based on the master model with a taper of 10° and 30° using computer-aided design software. Twenty monolithic 3rd generation translucent zirconia crowns were produced for each model with pre-defined cement space set to either 30 μm or 60 μm (n = 60). The estimated cement thickness was assessed by the replica method. The cemented crowns were loaded centrally in the occlusal fossa at 0.5 mm/min until fracture. Fractographic analyses were performed on all fractured crowns. Results The load at fracture was statistically significant different between the groups (p < 0.05). The crowns with 30° taper fractured at lower loads than those with 10° and 15° taper, regardless of the cement space (p < 0.05). The fracture origin for 47/60 crowns (78%) was in the cervical area, close to the top of the curvature in the mesial or distal crown margin. The remaining fractures started at the internal surface of the occlusal area and propagated cervically. Significance The fracture resistance of the monolithic zirconia crowns was lower for crowns with very large taper compared to 10 and 15° taper even though the crown walls were thicker.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleThe effect of preparation taper on the resistance to fracture of monolithic zirconia crownsen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2021 The Author(s)en_US
cristin.ispublishedfalse
cristin.fulltextoriginal
cristin.qualitycode2
dc.identifier.doi10.1016/j.dental.2021.03.012
dc.identifier.cristin1909262
dc.source.journalDental Materialsen_US
dc.source.pagenumbere427-e434en_US
dc.identifier.citationDental Materials. 2021, 37 (8), e427-e434.en_US
dc.source.volume37en_US
dc.source.issue8en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal