Vis enkel innførsel

dc.contributor.authorEkelund, Oskar
dc.contributor.authorHetland, Marit Andrea Klokkhammer
dc.contributor.authorLöhr, Iren Høyland
dc.contributor.authorSchön, Thomas
dc.contributor.authorSomajo, Sofia
dc.date.accessioned2022-03-24T08:33:26Z
dc.date.available2022-03-24T08:33:26Z
dc.date.created2022-01-04T20:46:51Z
dc.date.issued2021
dc.identifier.issn0305-7453
dc.identifier.urihttps://hdl.handle.net/11250/2987223
dc.description.abstractBackground Even though both EUCAST and CLSI consider broth microdilution (BMD) as the reference method for antimicrobial susceptibility testing (AST) of colistin, the method exhibits potential flaws related to properties of the colistin molecule. Objectives To develop a flow cytometry method (FCM) for colistin AST and to validate it against BMD, a commercial screening test and WGS. Methods Colistin-mediated loss of membrane integrity in Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter spp. was detected with the fluorescent probe YoPro-1 by FCM. An international collection of 65 resistant and 109 susceptible isolates were analysed and the colistin concentration required to reach the EC50 was compared with the BMD MIC and the presence of genotypic resistance markers. Results The overall FCM sensitivity and specificity for colistin resistance was 89% and 94%, with E. coli > K. pneumoniae > P. aeruginosa, whereas the performance for Acinetobacter spp. was poor. All tested E. coli were correctly categorized. Three K. pneumoniae isolates with genotypic findings consistent with colistin resistance were detected by FCM but not BMD. Compared with BMD, FCM delivered AST results with a 75% reduction of time. Conclusions Here, we present a rapid FCM-based AST assay for qualitative and quantitative testing of colistin resistance in E. coli and K. pneumoniae. The assay revealed probable chromosomal colistin resistance in K. pneumoniae that was not detected by BMD. If confirmed, these results question the reliability of BMD for colistin testing.en_US
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.rightsNavngivelse-Ikkekommersiell 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/deed.no*
dc.titleRapid high-resolution detection of colistin resistance in Gram-negative bacteria using flow cytometry: a comparison with broth microdilution, a commercial screening test and WGSen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright The Author(s) 2021en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2
dc.identifier.doi10.1093/jac/dkab328
dc.identifier.cristin1974766
dc.source.journalJournal of Antimicrobial Chemotherapyen_US
dc.source.pagenumber3183-3191en_US
dc.identifier.citationJournal of Antimicrobial Chemotherapy. 2021, 76 (12), 3183-3191.en_US
dc.source.volume76en_US
dc.source.issue12en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse-Ikkekommersiell 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse-Ikkekommersiell 4.0 Internasjonal