Vis enkel innførsel

dc.contributor.authorPallesen, Ståle
dc.contributor.authorGrønli, Janne
dc.contributor.authorMyhre, Kenneth
dc.contributor.authorMoen, Frode
dc.contributor.authorBjorvatn, Bjørn
dc.contributor.authorHanssen, Ingar
dc.contributor.authorHeglum, Hanne Siri Amdahl
dc.date.accessioned2019-11-12T12:54:45Z
dc.date.available2019-11-12T12:54:45Z
dc.date.issued2018
dc.PublishedPallesen S, Grønli J, Myhre K, Moen F, Bjorvatn B, Hanssen I, Heglum HSA. A pilot study of impulse radio ultra wideband radar technology as a new tool for sleep assessment. Journal of Clinical Sleep Medicine (JCSM). 2018;14(7):1249-1254.eng
dc.identifier.issn1550-9397
dc.identifier.issn1550-9389
dc.identifier.urihttps://hdl.handle.net/1956/20982
dc.description.abstractStudy Objectives To validate Impulse radio ultra wideband pulse-doppler radar technology against polysomnography (PSG) for sleep assessment. Methods In all, 12 participants were recruited and their overnight sleep was assessed both by a Novelda XeThru radar and PSG. Two subjects had two nightly recordings, whereas 10 had one recording. Epoch by epoch (30 seconds) comparisons from bedtime to rise time were conducted. Concordance was estimated in terms of the mean difference between the radar and the PSG estimates regarding sleep onset latency, wake time after sleep onset and total sleep time. In addition, accuracy, sensitivity, specificity and Cohen kappa were calculated. Results The mean difference (minutes) between the radar and the PSG registrations was −5.7 minutes (standard deviation [SD] = 22.1 minutes) for sleep onset latency, 6.4 minutes (SD = 32.5 minutes) for wake after sleep onset, and 1.5 minutes (SD = 24.6 minutes) for total sleep time. The mean values obtained for accuracy, sensitivity, specificity and Cohen kappa were 0.931, 0.961, 0.695 and 0.670, respectively. Conclusion Impulse radio ultra wideband radar technology is a promising tool in terms of affordable and practical objective sleep assessment. Further technical development and more validation studies are needed in order to conclude about the utility potential of this device.en_US
dc.language.isoengeng
dc.publisherAmerican Academy of Sleep Medicineeng
dc.titleA pilot study of impulse radio ultra wideband radar technology as a new tool for sleep assessmenteng
dc.typePeer reviewed
dc.typeJournal article
dc.date.updated2019-09-17T07:17:03Z
dc.description.versionacceptedVersion
dc.identifier.doihttps://doi.org/10.5664/jcsm.7236
dc.identifier.cristin1603980
dc.source.journalJournal of Clinical Sleep Medicine (JCSM)