Comparing screening outcomes for digital breast tomosynthesis and digital mammography by automated breast density in a randomized controlled trial: Results from the to-be trial
Moshina, Nataliia; Aase, Hildegunn Siv; Danielsen, Anders Skyrud; Haldorsen, Ingfrid S.; Lee, Christoph I.; Zackrisson, Sophia; Hofvind, Solveig
Journal article, Peer reviewed
Published version
Åpne
Permanent lenke
https://hdl.handle.net/11250/2763673Utgivelsesdato
2020Metadata
Vis full innførselSamlinger
- Department of Clinical Medicine [2095]
- Registrations from Cristin [10399]
Sammendrag
Background: Digital breast tomosynthesis (DBT) is considered superior to digital mammography (DM) for women with dense breasts.
Purpose: To identify differences in screening outcomes, including rates of recall, false-positive (FP) findings, biopsy, cancer detection rate, positive predictive value of recalls and biopsies, and histopathologic tumor characteristics by density using DBT combined with two-dimensional synthetic mammography (SM) (hereafter, DBT+SM) versus DM.
Materials and Methods: This randomized controlled trial comparing DBT+SM and DM was performed in Bergen as part of BreastScreen Norway, 2016–2017. Automated software measured density (Volpara Density Grade [VDG], 1–4). The outcomes were compared for DBT+SM versus DM by VDG in descriptive analyses. A stratified log-binomial regression model was used to estimate relative risk of outcomes in subgroups by screening technique.
Results: Data included 28 749 women, 14 380 of whom were screened with DBT+SM and 14 369 of whom were screened with DM (both groups: median age, 59 years; interquartile range [IQR], 54–64 years). The recall rate was lower for women screened with DBT+SM versus those screened with DM for VDG 1 (2.1% [81 of 3929] vs 3.3% [106 of 3212]; P = .001) and VDG 2 (3.2% [200 of 6216] vs 4.3% [267 of 6280]; P = .002). For DBT+SM, adjusted relative risk of recall (VDG 2: 1.8; P < .001; VDG 3: 2.4; P < .001; VDG 4: 1.8; P = .02) and screen-detected breast cancer (VDG 2: 2.4; P = .004; VDG 3: 2.8; P = .01; VDG 4: 2.8; P = .05) increased with VDG, whereas no differences were observed for DM (relative risk of recall for VDG 2: 1.3; P = .06; VDG 3: 1.1; P = .41; VDG 4: 1.1; P = .71; and relative risk of screen-detected breast cancer for VDG 2: 1.7; P = .13; VDG 3: 2.1; P = .06; VDG 4: 2.2; P = .15).
Conclusion: Screening with digital breast tomosynthesis combined with synthetic two-dimensional mammograms (DBT+SM) versus digital mammography (DM) yielded lower recall rates for women with Volpara Density Grade (VDG) 1 and VDG 2. Adjusted relative risk of recall and screen-detected breast cancer increased with denser breasts for DBT+SM but not for DM.