Vis enkel innførsel

dc.contributor.authorToft, Johanne Holm
dc.contributor.authorDalen, Ingvild
dc.contributor.authorSkadberg, Øyvind
dc.contributor.authorGøransson, Lasse Gunnar
dc.contributor.authorØkland, Inger
dc.contributor.authorBleskestad, Inger Hjørdis
dc.date.accessioned2022-11-02T13:24:34Z
dc.date.available2022-11-02T13:24:34Z
dc.date.created2022-10-31T13:43:58Z
dc.date.issued2022
dc.identifier.issn2398-9238
dc.identifier.urihttps://hdl.handle.net/11250/3029627
dc.description.abstractIntroduction: Glycated albumin (GA), a biomarker reflecting short-term glycaemia, may be useful to assess glycaemic control in pregnancy. We examined the association between GA and continuous glucose monitoring (CGM) metrics across gestation. Methods: In this prospective cohort study including 40 women with pre-gestational diabetes, blood samples for analysis of GA and glycated haemoglobin A1c (HbA1c) were collected at pregnancy week 12, 20, 24, 28, 32 and 36. In the CGM-group (n = 19), CGM data were collected from first trimester until pregnancy week 36. Receiver operating characteristic (ROC) curves were used to assess the accuracy of GA and HbA1c to detect poor glycaemic control, using CGM metrics as the reference standard. This study was conducted at Stavanger University Hospital, Norway, in 2016–2018. Results: Glycaemic control improved across gestation with more time spent in target range, coinciding with decreased glycaemic variability and lower mean GA level. There was statistically significant correlation between GA and most CGM metrics. The area under the ROC curves (AUC) for detecting time in range <70% and time above range >25% for the pregnancy glucose target 63–140 mg/dl (3.5–7.8 mmol/L) were 0.78 and 0.82 for GA, whereas AUCs of 0.60 and 0.72 were found for HbA1c, respectively. Conclusions: Higher GA levels were associated with less time spent in target range, more time spent in the above range area and increased glycaemic variability. GA was more accurate than HbA1c to detect time above range >25% and time in range <70%.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleGlycated albumin and continuous glucose monitoring metrics across pregnancy in women with pre-gestational diabetesen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2022 the authorsen_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1002/edm2.376
dc.identifier.cristin2066844
dc.source.journalEndocrinology, Diabetes & Metabolismen_US
dc.identifier.citationEndocrinology, Diabetes & Metabolism. 2022.en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal