Show simple item record

dc.contributor.authorMarkussen, Dagfinn Lunde
dc.contributor.authorEbbesen, Marit Helen
dc.contributor.authorSerigstad, Sondre
dc.contributor.authorKnoop, Siri Tandberg
dc.contributor.authorRitz, Christian
dc.contributor.authorBjørneklett, Rune Oskar
dc.contributor.authorKommedal, Øyvind
dc.contributor.authorJenum, Synne
dc.contributor.authorUlvestad, Elling
dc.contributor.authorGrewal, Harleen
dc.date.accessioned2024-05-07T13:59:03Z
dc.date.available2024-05-07T13:59:03Z
dc.date.created2023-11-23T13:37:28Z
dc.date.issued2023
dc.identifier.issn2165-0497
dc.identifier.urihttps://hdl.handle.net/11250/3129564
dc.description.abstractThis prospective study assessed the value of initial microscopy evaluation of sputum samples submitted for rapid syndromic PCR-based testing. Bacterial detections by the BioFire FilmArray Pneumonia Panel plus in 126 high- and 108 low-quality sputum samples, based on initial microscopy evaluation in samples from patients with lower respiratory tract infections were compared. We found that high-quality samples had a higher proportion of bacterial detections compared to low-quality samples (P = 0.013). This included a higher proportion of detections of bacteria deemed clinically relevant by predefined criteria (70% and 55%, P = 0.016), as well as a higher proportion of detections of Haemophilus influenzae (36% and 20%, P = 0.010). High-quality samples also had more detections of bacteria with high semi-quantitative values. The study found no significant difference between high- and low-quality samples in the proportions of samples with a single species of bacteria detected, samples with a bacteria treated by the clinician, samples with detection of a proven etiology of community-acquired pneumonia by predefined criteria, the number of bacterial species detected, or the detection of Streptococcus pneumoniae, Moraxella catarrhalis, or Staphylococcus aureus. The results showed that 40% (95% CI 35%–47%) of the bacterial detections would have been missed if only high-quality samples were analyzed. This included 41% (27%–56%) of detections of S. pneumoniae, 33% (23%–45%) of detections of H. influenzae, 42% (28%–58%) of detections of S. aureus, and 37% (23%–54%) of detections of M. catarrhalis. These findings suggest that all sputum samples submitted for rapid syndromic PCR testing should be analyzed, regardless of initial microscopy quality assessment.en_US
dc.language.isoengen_US
dc.publisherAmerican Society for Microbiologyen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleThe diagnostic utility of microscopic quality assessment of sputum samples in the era of rapid syndromic PCR testingen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright 2023 the authorsen_US
dc.source.articlenumbere03002-23en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1
dc.identifier.doi10.1128/spectrum.03002-23
dc.identifier.cristin2201062
dc.source.journalMicrobiology spectrumen_US
dc.identifier.citationMicrobiology spectrum. 2023, 11 (5), e03002-23.en_US
dc.source.volume11en_US
dc.source.issue5en_US